• schmidtster@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        10 months ago

        Older receptacles and even modern receptacles and cords do still make use of their holes.

        It’s why if the holes are included there is specs they must follow.

        This plug makes use of the holes for a solid mechanical connection that will only be removed when you pull on the collar to remove the pin that goes through the holes.

    • schmidtster@lemmy.world
      link
      fedilink
      arrow-up
      5
      arrow-down
      4
      ·
      10 months ago

      If it’s for manufacturing why are some made without them?

      Theres patents out there, I don’t know why technology connection did his own experiments on modern plugs instead of a modicum of research about receptacles.

      • NarrativeBear@lemmy.world
        link
        fedilink
        arrow-up
        4
        arrow-down
        1
        ·
        10 months ago

        Not exactly sure, I think it’s just one of those things were we “people” have gotten so used to the design and how it’s supposed to look, that even if it’s not needed we keep doing it.

        Since multiple companies manufacturer plugs and connections, some manufacturers may not need the holes as a part of the assembly process. Other may opt not to add them as they do not have a purpose (other then how we perceive a north america plug is supposed to look like).

        Funny story, almost all standard north america three prong plug are installed upside down. The third “center prong” or “ground” is actually on the top per the original design.

        Most new builds and electricians are opting to install this way now. The orientation has no impact on performance.

        • Zoot@reddthat.com
          link
          fedilink
          arrow-up
          3
          ·
          10 months ago

          Except that if a plug falls out, you want it to stay grounded… meaning the ground should absolutely be on the bottom because gravity.

          • FutileRecipe@lemmy.world
            link
            fedilink
            arrow-up
            1
            arrow-down
            1
            ·
            10 months ago

            the ground should absolutely be on the bottom because gravity.

            Not necessarily. You typically want the ground longer so it’s the first in and last out. Type G has the ground on top. I vaguely remember hearing that’s because if it comes slightly out and something sharp or metal falls on the plug, you want it to hit the ground and not the live part…but I don’t know how reliable that story is.

            • schmidtster@lemmy.world
              link
              fedilink
              arrow-up
              1
              ·
              edit-2
              10 months ago

              Some electricians started doing it since it became a viral Internet trend to intentionally drop quarters onto the prongs of a slightly pulled out plug.

              In history there’s only been a few cases of a fires being started because of an accidental thing falling on the plugs. The breaker trips before a fire would start in almost all cases. Provided the breaker isn’t faulty or something. Which you should be testing regularly as a home owner.

        • schmidtster@lemmy.world
          link
          fedilink
          arrow-up
          2
          arrow-down
          1
          ·
          10 months ago

          There’s patents with these features specified for locking and even modern patents reference these old patents.

          Technology connections got it wrong, it happens.