    I’m not American, but I’ve lived a few years in the US. I find it very interesting that the US invented the electric infrastructure that we use today, but they really screwed up a few things. Firstly, the connectors are far too unsafe. They are flimsy and have no protection from electrocution. Secondly, by using 120V as the main voltage, you need more current to do the same amount of work as a 240V system. Thay means thicker wires, more stress on the plugs, and greater fire hazards.

    Shuko plugs FTW

    • Ranvier@sopuli.xyz
      link
      fedilink
      arrow-up
      29
      arrow-down
      2
      ·
      edit-2
      1 year ago

      Common misconception about the voltage though, the US does have a 240v system (well in houses, some places have three phase power which gets weird). The breakers can be wired to give 120v or 240v. The large appliances like driers or electric car chargers and things that do need a large ampunt of current get wired up for that. It’s really only a slightly slower electric kettle to deal with as a minor inconvenience. Or maybe if you wanted an absolutely enormous electric space heater or something, but those are dangerous as it is. Not a lot of things used need more than the 1800 watt maximum. As far as I can tell it’s just a relic of history, Edison ran his generators at about 110v originally and that’s the voltage original light bulb filaments wanted and higher voltage filaments weren’t used until after the US had already been electrifying to a good extent. Theoretically 120v might be a little safer from a getting shocked standpoint, but electrocutions are pretty rare as it is, just a historical artifact and not a conscious design choice as far as I can tell (and yes, volts do matter too, not just amps. Especially if what’s being shocked has very high resistance, like human skin).

      Technology connections has a fun video on this too in addition to the plug hole video someone linked elsewhere: https://youtu.be/jMmUoZh3Hq4?si=4a1SCYOZUy-1z2h_

      • fidodo@lemmy.world
        link
        fedilink
        arrow-up
        17
        ·
        1 year ago

        I’ve used electric kettles in the US and Europe and they’re barely slower. I think the difference is overstated. It’s often used as the reason that fewer Americans have kettles but I think the real reason is just that Americans drink fewer hot beverages other than coffee, and most people have a machine for that.

        While 120v is safer for shocks I think the greater safety reason for 240 is lower fire risk which is more common and dangerous that shocks in either system.

    • fidodo@lemmy.world
      link
      fedilink
      arrow-up
      27
      arrow-down
      1
      ·
      1 year ago

      It’s not surprising. If you’re first to adopt something by the time you realize how it could be improved you’re locked into what you did. It happens with all kinds of early adoption. I noticed it a lot in Japan which picks up tech really quickly but as a result has been left with a bunch of crufty old systems. Like they were way ahead on contactless payment, but now they have a bunch of complex and confusion payment systems and lots of them don’t support credit cards while the rest of the world just has contactless credit cards.

    • whyNotSquirrel@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      18
      ·
      1 year ago

      yeah but it looks like a funny face!

      I didn’t know that schuko plugs are the norm for most Europe countries, I thought it was a German thing

      https://en.wikipedia.org/wiki/Schuko

      • TimeNaan@lemmy.world
        link
        fedilink
        arrow-up
        12
        ·
        edit-2
        1 year ago

        Also the french system is compatible with Schuko, so that makes it even more universal.

          • TimeNaan@lemmy.world
            link
            fedilink
            arrow-up
            4
            ·
            1 year ago

            It would be from a financial standpoint. Changing a standard this widely implemented is very costly.

            Why change it if they’re compatible anyways? Most devices in the eu are designed to accomodate both, its just a question of the earth pin being different.

            I’ve travelled all across europe, coming from a country with the french style outlets. I never had any problems connecting anything except for Switzerland and Italy, because they stuck to their own (inferior) standard thats not compatible with anything else.

            • sarmale@lemmy.zip
              link
              fedilink
              arrow-up
              3
              ·
              edit-2
              1 year ago

              The smaller devices like chargers and small lamps have a euro plug that can plug in schucko, danish, italian, swiss, french (but not british)

              • TimeNaan@lemmy.world
                link
                fedilink
                arrow-up
                1
                ·
                1 year ago

                You’re right, I forgot about that. But good luck plugging your laptop or hair dryer in without some janky adapter.

                • sarmale@lemmy.zip
                  link
                  fedilink
                  arrow-up
                  2
                  ·
                  1 year ago

                  A laptop you can plug in all of Europe. But a hairdryer you cant because (at least mine) uses a schucko plug (but without ground so wtf)

    • Kethal@lemmy.world
      link
      fedilink
      arrow-up
      13
      arrow-down
      1
      ·
      edit-2
      1 year ago

      Many people from other countries fret about the unsafe plugs in the US. They of course do not have the same level of safety, but it also doesn’t appear to matter. I have never been shocked inserting or removing a US plug. I don’t know and haven’t heard of anyone who has. People do get shocked, but for other reasons.

      • Ookami38@sh.itjust.works
        link
        fedilink
        arrow-up
        14
        ·
        1 year ago

        I have, but I was a child and very much not plugging it in the right way. It was in a very cramped space I couldn’t see, and dumbass me thought holding the metal would give me better control. It did, I made it into the plug.

        • AA5B@lemmy.world
          link
          fedilink
          arrow-up
          2
          ·
          edit-2
          1 year ago

          Did you die? I wonder about the truth behind the idea that getting shocked with 120v is less likely/hazardous than double that

          • brakenium@lemm.ee
            link
            fedilink
            arrow-up
            1
            ·
            1 year ago

            As a kid I used a metal tool to cut a live wire 220v-240v wire and besides getting scared by the jolt I was fine. Probably because the protection circuits kicked in

            • AA5B@lemmy.world
              link
              fedilink
              arrow-up
              2
              ·
              1 year ago

              As an idiot, I’ve gotten shocked by 120v multiple times and 240v once. That hurt a lot more. Hopefully I have survived long enough so far to be less of an idiot

      • MufinMcFlufin@lemmy.world
        link
        fedilink
        arrow-up
        3
        ·
        1 year ago

        The one time I’ve had an issue with our plugs (that would have been solved by something like the British plug design) was when I wasn’t paying attention to a remote antenna resting on top of a loose plug. Accidentally caused a short that melted that little bit of wire but nothing else happened. Just had a black spot on that outlet from then onward.

        I have shocked myself on one once but just like with the other person replying that was as a child and felt more like a learning experience to not mess with outlets.

        • XeroxCool@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          1 year ago

          This is exactly why I like having “upside down” US plugs where the ground pin is on top. If there’s a ground pin in the plug, it prevents pennies and paperclips from falling onto the hot and neutral pins. Unfortunately, this isn’t as common because 1. Some contractors beleive it’s illegal, 2. Many wall wart adapters and lay flat plugs assume the receptacle goes ground pin down, and 3. It doesn’t look like a shocked face.

          • Thisfox@sopuli.xyz
            link
            fedilink
            arrow-up
            1
            ·
            1 year ago

            If your plug is not plugged in completely flush with the wall power point so a penny (or etc) can fit between the plug and powerpoint and yet the power can get through, then there is something very wrong.

            • XeroxCool@lemmy.world
              link
              fedilink
              arrow-up
              1
              ·
              1 year ago

              It happens all the time across the country. Crusty metal debris and Light-pressure low-surface area contact can cause a hot burning short before tripping the breaker. The contact is also inconsistent as it melts and breaks contact, further delaying the breaker trip before it falls back down. There’s literally a tiktok challenge with plenty of burnt outlets, plugs, and pennies available for your viewing pleasure

    • moitoi@lemmy.dbzer0.com
      link
      fedilink
      arrow-up
      4
      ·
      1 year ago

      Type J > Shuko

      Type J is safe and a better implementation. I don’t know why the EU didn’t choose type J as a standard.

    • AA5B@lemmy.world
      link
      fedilink
      arrow-up
      4
      ·
      edit-2
      1 year ago

      I think the distinction is we don’t use general purpose 240v receptacles. We only use them as dedicated circuits for built in major appliances. Historically that was sufficient.

      We also don’t really use 20a outlets. I don’t know why, especially now that we require 20a circuits in a few places, but you rarely see 20a outlets or appliances with 20a plugs, even though a lot of small appliances could benefit from a little extra power

      So is there really a need? Electric kettles are a perfect scenario but what else? Most other use cases for 240v are “built in” appliances not likely to move (welder, air conditioner, laundry, range, etc). Space heaters and hot plates are already dangerous enough that allowing double the current seems like a hazard

      • Darkassassin07@lemmy.ca
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 year ago

        Space heaters and hot plates are already dangerous enough that allowing double the current seems like a hazard

        You’d require half the current for the same wattage at 240v. At most, it’s the same 15a max, with double the voltage.

        Tbh I think I’d rather achieve the same heat output by running them at 240v using less current instead of 110v and pulling as much current as possible/permitted (15a).

        Insulation is cheaper than actual conductors too. Higher voltage and lower current means thinner conductors with more insulation to protect them. You’d also remove complexity and thus cost by only needing one voltage. No need for a split phase supply.

        I think 240v would be a better option. 🇨🇦

    • sock@lemmy.world
      link
      fedilink
      arrow-up
      5
      arrow-down
      2
      ·
      1 year ago

      u fool if the plugs functioned consistently and were made intelligently that might cost extra money and would DEMOLISH the rich peoples pockets we cant have that. who’s gonna profit off my taxes?

    • ThePowerOfGeek@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 year ago

      On your first point, the plugs have improved quite a lot in the last 10 or so years. Still not enough compared to most other Western standards, and it’s taken to long. But they have improved.

      …Just in time for USB plugs and sockets to start taking off. Though I’m not sure how big a deal those are when it comes to safety.